機房斷電后重啟pg數據庫,報如下錯誤:

 2019-01-01 22:42:59.240 EST >LOG: database system was interrupted while in recovery at 2019-01-01 22:00:58 EST
 2019-01-01 22:42:59.240 EST >HINT: This probably means that some data is corrupted and you will have to use the last backup for recovery.
 2019-01-01 22:42:59.241 EST >LOG: database system was not properly shut down; automatic recovery in progress
 2019-01-01 22:42:59.333 EST >PANIC: unexpected pageaddr 26EA/46000000 in log segment 00000001000026EA00000017, offset 0
 2019-01-01 22:42:59.333 EST >LOG: startup process (PID 88586) was terminated by signal 6: Aborted
 2019-01-01 22:42:59.333 EST >LOG: aborting startup due to startup process failure

修復方法:

切換到bin目錄下:

cd /usr/pgsql-9.3/bin

使用pg_resetxlog命令修復日志:(/var/lib/pgsql/9.3/data為pg_data的目錄)

pg_resetxlog -f /var/lib/pgsql/9.3/data

重啟數據庫:

pg_ctl start

補充:PostgreSQL 數據庫服務無法啟動的解決方法

因為客戶那邊的磁盤一般是FAT32的文件系統(tǒng),所以我們程序安裝時,采用手動安裝PostgreSQL的形式安裝數據庫,但初始化數據庫群成功并且成功注冊了系統(tǒng)服務后,

發(fā)現PostgreSQL的服務總是啟動不了,提示服務啟動又停止了,然后在系統(tǒng)時間查看器里發(fā)現報的錯誤是:Could not create inherited socket, 錯誤編碼為10022

解決方法:

運行 netsh winsock reset,重啟電腦,OK!

以上為個人經驗,希望能給大家一個參考,也希望大家多多支持腳本之家。如有錯誤或未考慮完全的地方,望不吝賜教。

您可能感興趣的文章:
  • Postgresql 默認用戶名與密碼的操作
  • postgresql 中的加密擴展插件pgcrypto用法說明
  • PostgreSQL表膨脹監(jiān)控案例(精確計算)
  • postgresql 如何關閉自動提交
  • PostgreSQL 恢復誤刪數據的操作
  • PostgreSQL 日志文件的所在位置
  • PostgreSQL 實現登錄及修改密碼操作

標簽:辛集 溫州 杭州 昭通 濮陽 海西 寶雞 榆林

巨人網絡通訊聲明:本文標題《Postgresql 解決pg掉電后無法重啟的問題》,本文關鍵詞  Postgresql,解決,掉電,后,無法,;如發(fā)現本文內容存在版權問題,煩請?zhí)峁┫嚓P信息告之我們,我們將及時溝通與處理。本站內容系統(tǒng)采集于網絡,涉及言論、版權與本站無關。
  • 相關文章
  • 下面列出與本文章《Postgresql 解決pg掉電后無法重啟的問題》相關的同類信息!
  • 本頁收集關于Postgresql 解決pg掉電后無法重啟的問題的相關信息資訊供網民參考!
  • 推薦文章